Mag-flux A

Magnetic-inductive sensor for a wide range of applications

Our magnetic-inductive sensors (MID) are precision measurement devices and suitable for linear flow measurement of almost all electrically conductive liquids, as well as slurries, pulps and pastes. Thanks to the magnetic field’s properties, these devices can be used for flow speeds up to 10 m/s (32.8 ft/s) and for a minimum conductivity of 20 / 3 µS/cm.

The flow meter consists of a sensor and a corresponding measuring transducer. They are available both in separate and in compact designs.

Operating principlepulsed constant field (DC)
Measuring accuracy¹error of measurement: ± 0,5 % of MV
repeatability: ± 0,15 % of MV
Liquidsmin. conductivity: 20 μS/cm (optional 3µS/cm)
min. flow velocity: 0.25 m/s (0.82 ft/s)
max. flow velocity: 10 m/s (32.8 ft/s)
Temperature limits²soft rubber: 0 °C bis +90 °C
hard rubber: 0 °C bis +90 °C
PTFE liner: -20 °C bis +180 °C (16 bar)
Tube materialsstainless steel Mat. No. 1.4301
(or better)
Electrodes materialsstainless steel Mat. No. 1.4571,
Hastelloy® C4, titanium, tantalum,
platinum, Monel®
Process connectionsDIN 2501: DN 15 – DN 2000
ANSI B16.5: 1/2″ – 24″
AWWA: 4″ – 80″
Table: DN 15 – DN 2000

¹ all values are valid from 0.25 m/s – 10 m/s (0.82 ft/s  – 32.8 ft/s)

² for PTFE the max. temperatur decreases with increasing pressure